FirstLine Gloves
(888) 688-6768
Contact Us

Virepel - Latex Examination Glove

Virepel - Double Polymer Coated Latex Exam Glove
Latex High-Risk
NFPA 1999-2008 Certified
10" Length
12 Mil Thickness
Double Polymer Coated / Non Chlorinated
50 box / 10 box case
Download Product Sheet
Download Bid Specification

Double Polymer Coated Latex Exam Glove

Premier Attributes

  • NFPA 1999-2008 Certified by Underwriters Laboratories
  • Double Polymer Coated - Non-Chlorinated, Powder-Free, Custom Formulation
  • Dramatically reduces barrier degradation when exposed to high heat temperatures – increases shelf life
  • Certified Watertight AQL 1.0 provides minimal exposure to pathogens from pinhole failures
  • High Risk thickness combined with 10" length provides extra protection at a savings
  • Low in proteinsurpasses FDA and NFPA requirements of <50 ug/g
  • Hi Tack – Full texture surface designed to increase grip even when wet
  • Proprietary Latex Formulation significantly exceeds ASTM and NFPA requirements for tensile, elongation and watertight properties
  • Maximum lot size of 600,000 gloves tested and certified by a third-party independent laboratory
  • Gloves test below detectable levels for all chemicals, identified by OSHA, that contribute to allergies

Quality Standards

  • NFPA 1999 - 2008 Edition- National Fire Protection Agency Standard on Protective Clothing
  • ASTM D3578- Standard Specification for Rubber Examination Gloves
  • ASTM D412- Vulcanized Rubber and Thermoplastic Elastomers – Tension 1
  • ASTM D412 (NFPA Modification)- Ultimate Elongation Percentage Following 100% Isopropanol Soak for 2 Hours
  • ASTM D573- Standard Test Method for Rubber – Deterioration in an Air Oven
  • ASTM F1671 (NFPA Modification)- Standard Test Method for Bacteriophage Penetration Resistance on Whole Gloves
  • ASTM F1342- Standard Test Method for Protective Clothing Material Resistance to Puncture
  • ASTM D5712- Modified Lowry Assay – Total Water Extractable Protein per Gram
  • ASTM D5151- Standard Test Method for Detection of Holes in Medical Gloves
  • ASTM D6124- Standard Test Method for Residual Powder on Medical Gloves
  • NFPA Dexterity Test- Crawford Small Parts Dexterity Test, Screws Technique

Performance Standards

NFPA Standards ASTM D6319 Virepel Standards
Tensile Before Aging 13.8MPa 14MPa 28MPa
Tensile After Aging 13.8MPa 14MPa 25MPa
Elongation Before Aging 500% 500% 850%
Elongation After Aging 500% 400% 850%
Watertight Barrier AQL 1.5 2.5 .65
Puncture 4.5 N N/A 7.1 N
Protein Content <50 ug/g <200 ug/dm2 <50 ug/g

Specifications

Thickness (mil)
Min Avg
Finger 12.0 13.2
Palm 9.0 10.3
Cuff 6.0 7.8
Surface Features Full Texture
Process Properties Double Polymer Coated
Non Chlorinated
Material Powder-Free Latex
Fit / Cuff Ambidextrous/Beaded
Length 10"

50 Gloves per box / 10 boxes per case
Part Number Glove Size Palm Width (mm) Tolerance +5
1LVRLG-S Small 82
1LVRLG-M Medium 92
1LVRLG-L Large 105
1LVRLG-XL X-Large 110
1LVRLG-2XL 2X-Large 115